This is an old revision of this page, as edited by MatthewVanitas (talk | contribs) at 21:59, 25 December 2008 (Added category, please categorise your articles in the future). The present address (URL) is a permanent link to this revision, which may differ significantly from the current revision.

Correlated Double Sampling(CDS) is a technique for measuring electrical values such as voltages or currents that allows for removal of an undesired offset. It is used quite frequently when measuring sensor outputs. The output of the sensor is measured twice: once in a known condition and once in an unknown condition. The value measured from the known condition is then subtracted from the unknown condition to generate a value with a known relation to the physical quantity being measured.